Products detail
This page lists 10 models. Plain-text version (smaller, for AI tools): https://www.taiwan-machine.com/p/1845.txt
Specifications in text (HTML) for search engines and AI. Please confirm details with EASTAR sales before ordering.
E -A350
E -A350 specifications| Rated capacity (KVA) | 35 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 98 |
|---|
| Maximum short-circuit current (A) | 16,000 |
|---|
| Maximum pressure force (Kg/cm²) | 560 |
|---|
| Permit usage (%) | 6.37 |
|---|
| Deep throat (mm) | 400 |
|---|
E -A500
E -A500 specifications| Rated capacity (KVA) | 50 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 135 |
|---|
| Maximum short-circuit current (A) | 18,500 |
|---|
| Maximum pressure force (Kg/cm²) | 560 |
|---|
| Permit usage (%) | 6.85 |
|---|
| Deep throat (mm) | 400 |
|---|
E -A600
E -A600 specifications| Rated capacity (KVA) | 60 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 146 |
|---|
| Maximum short-circuit current (A) | 20,000 |
|---|
| Maximum pressure force (Kg/cm²) | 580 |
|---|
| Permit usage (%) | 8.44 |
|---|
| Deep throat (mm) | 400 |
|---|
E -A800
E -A800 specifications| Rated capacity (KVA) | 80 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 225 |
|---|
| Maximum short-circuit current (A) | 25,000 |
|---|
| Maximum pressure force (Kg/cm²) | 770 |
|---|
| Permit usage (%) | 6.32 |
|---|
| Deep throat (mm) | 450 |
|---|
E -A1000
E -A1000 specifications| Rated capacity (KVA) | 100 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 285 |
|---|
| Maximum short-circuit current (A) | 30,000 |
|---|
| Maximum pressure force (Kg/cm²) | 770 |
|---|
| Permit usage (%) | 6.16 |
|---|
| Deep throat (mm) | 450 |
|---|
E -A1200
E -A1200 specifications| Rated capacity (KVA) | 120 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 318 |
|---|
| Maximum short-circuit current (A) | 35,000 |
|---|
| Maximum pressure force (Kg/cm²) | 770 |
|---|
| Permit usage (%) | 7.11 |
|---|
| Deep throat (mm) | 450 |
|---|
E -A1500
E -A1500 specifications| Rated capacity (KVA) | 150 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 462 |
|---|
| Maximum short-circuit current (A) | 42,000 |
|---|
| Maximum pressure force (Kg/cm²) | 1,000 |
|---|
| Permit usage (%) | 6.37 |
|---|
| Deep throat (mm) | 450 |
|---|
E -A2000
E -A2000 specifications| Rated capacity (KVA) | 200 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 576 |
|---|
| Maximum short-circuit current (A) | 48,000 |
|---|
| Maximum pressure force (Kg/cm²) | 1,000 |
|---|
| Permit usage (%) | 7.87 |
|---|
| Deep throat (mm) | 450 |
|---|
E -A2500
E -A2500 specifications| Rated capacity (KVA) | 250 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 583 |
|---|
| Maximum short-circuit current (A) | 53,000 |
|---|
| Maximum pressure force (Kg/cm²) | 1,500 |
|---|
| Permit usage (%) | 9.19 |
|---|
| Deep throat (mm) | 400 |
|---|
E -A3000
E -A3000 specifications| Rated capacity (KVA) | 300 |
|---|
| Rated primary voltage (V) | 220 / 440 |
|---|
| Rated frequency (HZ) | 50 / 60 |
|---|
| Maximum force (KVA) | 816 |
|---|
| Maximum short-circuit current (A) | 60,000 |
|---|
| Maximum pressure force (Kg/cm²) | 1,900 |
|---|
| Permit usage (%) | 6.75 |
|---|
| Deep throat (mm) | 400 |
|---|
E -A3000 features, standard and optional accessories
- E-A1500 (E-A1000~E-A3000); E-A500 (E-A350~E-A800).
- Air control cylinder construction and solenoid valve.
- High-performance air compression components. (Air F. L. Units).
- The cooling tubing employs bronze tube compulsory cooling cycle circuits.
- High precision digital pushbutton switch and synchronous IC control circuits.
- Transformer of excellent current conductivity and of minimium electric loss.
- Welding current circuits with adoption of SCR nocontact point switch.
- Can design & make according to local voltage requirement (200V-600V)
- Big Capacity Model Could be Equipped With 3 Phase Inverter Control System.